(以下为 HEIDENHAIN 官方《错误列表》TNC7 / TNC 640 / TNC 620 原文摘录)

错误说明(Error message)

  • E01C CC%2 非法FS功能ERR-ID=%4 ObjId=%5 Param=%6

原因(Cause of error)

  • The SPLC program has requested an illegal safety
  • function over PP_AxGrpStateReq in the ApiToSafety(symbolic memory interface of SPLC to the core safety
  • software SKERN).
  • ERR-ID = Exact information
  • ObjId = Axis group causing the error
  • Param = Depends on the ERR-ID
  • ERR_ID:
  • 100: Requested safety function is not supported
  • Param = Requested safety function
  • 200: The safety function SLI_S was requested for a axis
  • group that is not of the spindle type.
  • Param = No meaning
  • 300: The safety function SLI_2, SLI_3 or SLI_4 was
  • requested for an axis group that is of the spindle type.
  • This safety function is not allowed for spindles.
  • Param = Requested safety function
  • 400: The safety function SLS_4 or SLI_4 was requested
  • for a axis group and the function is not enabled.
  • Param = Requested safety function
  • 401: A direct change is requested from the safety
  • function SLS_2, SLI_2, SLS_3 or SLI_3 into the safety
  • function SLS_4 or SLI_4.
  • This direct change is not allowed.
  • Parameter = Requested safety function
  • 402: A direct change is requested from the safety
  • function SLS_4 or SLI_4 into the safety function SLS_2,
  • SLI_2, SLS_3 or SLI_3.
  • This direct change is not allowed.
  • Parameter = Requested safety function
  • 500: The SPLC requested the safety function STO or
  • STO_O for an axis group whose drives are still in the
  • control loop. The requested safety function can be
  • requested only if all drives of this axis group have been
  • switched off.
  • Parameter = Value of the required safety function

官方纠正措施(Error correction)

  • Check the ERR ID:
  • 100 - Use only safety functions that are supported with
  • this software level.
  • 200 - Request the safety function SLI_S only for axis
  • groups with spindles.
  • 300 - For spindles, request only the SLI_S function.
  • 400 - Do not request a safety function or enable the
  • safety related operating mode SOM 4 in machine
  • parameter permitSom4.(Check the preconditions for enabling)
  • 401 - Switch off the drives between the change of
  • safety function and request SOS for at least one cycle.
  • 402 - See 401

手册说明:本条错误编号 231-E01C 出自 HEIDENHAIN《错误列表》,适用于 TNC7 / TNC 640 / TNC 620 / CNC PILOT 640 / MANUALplus 620,具体适用机型请核对该手册的适用范围(原始第 467 页)。

标准化解决方法与排查步骤

  1. 记录 231-E01C 的报警号、发生时机与当时正在执行的动作(上电、回参考点、加工、换刀、通信)
  2. 在报警履历中确认第一个出现的报警:多个报警同时报出时,首个报警通常才是根因,后续多为连锁
  3. 对照该机型官方维修手册中 231-E01C 对应章节,确认触发条件与判定逻辑
  4. 按报警所属子系统(伺服 / 主轴 / 程序 / PMC / 外围)缩小范围,逐项排除
  5. 处置后清除报警,先空运行再单段试切,确认不再复现

本页所列步骤为针对 231-E01C 这一具体错误整理的操作顺序。手册本身未覆盖的情况,请以机床制造商的技术支持渠道为准。

维修注意事项与预防措施

  • 先备份再动手:修改参数或程序前,先用系统自带备份功能完整留存,异常时整体回写。

  • 记录原始状态:改动前记下相关参数原值、程序段与接线位置,便于回退。

  • 一次只改一处:同时改多处会让排查失去判断依据。

  • 安全第一:涉及轴移动、主轴旋转的检查,必须先确认机械处于安全位置、工件已松开工装。

  • 以手册为准:231-E01C 的确切含义与处置流程,以对应机型、对应版本的官方维修手册为唯一依据。


本页所列排查步骤基于 HEIDENHAIN 官方《错误列表》与现场经验整理,具体处置请以您所用机型、对应版本的官方手册为准。