FANUC ALM共82篇 第2页
This section mainly introduces the alarms and detailed descriptions of each FANUC system. Through this section, you can find common alarm solutions.
SV417 parameter illegal, diagnostic number 6402-FANUC CNC

SV417 parameter illegal, diagnostic number 6402

Problem phenomenon: SV417 parameter illegal when configuring grating ruler Solution: The value in diagnostic number 352 is 6402 Clear the relevant parameters of the fifth group of ...
share5的头像-FANUC CNC钻石会员share537天前
0589
Steps to resolve illegal FANUC SV417 servo parameters-FANUC CNC

Steps to resolve illegal FANUC SV417 servo parameters

SV417 servo parameter setting error, solution and steps are as follows: Solution: (1) Diagnosis data No.203 # 4=0: The parameters detected by CNC are illegal. Details confirm diagn...
share5的头像-FANUC CNC钻石会员share540天前
05814
FANUC ALARM 935 (SRAM ECC ERROR)-FANUC CNC

FANUC ALARM 935 (SRAM ECC ERROR)

FANUC ALARM 935 Causes and actions An ECC error occurred in the SRAM used to store data such as parametersand machining programs. This alarm is issued if the battery has run down o...
share5的头像-FANUC CNC钻石会员share51个月前
0579
FANUC system occasionally detects SV409 alarm-FANUC CNC

FANUC system occasionally detects SV409 alarm

cause of issue An abnormal load was detected on the servo motor, Cs axis, or spindle positioning axis. troubleshooting Check the load of the axis during movement; Confirm whether t...
share5的头像-FANUC CNC钻石会员share51个月前
0676
FANUC SP9021 Position sensor polarity error-FANUC CNC

FANUC SP9021 Position sensor polarity error

SP9021 Position sensor polarity error Amplifier alarm number: 21 Reason for alarm: wrong polarity of position sensor. Troubleshooting ideas: Please set P4000#0 and P4001#4 correctl...
share5的头像-FANUC CNC钻石会员share51个月前
06113
FANUC system PMC alarm ER07 alarm causes and solutions-FANUC CNC

FANUC system PMC alarm ER07 alarm causes and solutions

CNC system: fanuc system 0I-TC Alarm number: ER07 Alarm description: ER07 OPTION LADDER STEP Ladder diagram option function not found Reasons for alarm: 1. System data is lost. Sol...
share5的头像-FANUC CNC钻石会员share51个月前
06212
SP9115(S) PS CONTROL AXIS ERROR 2-FANUC CNC

SP9115(S) PS CONTROL AXIS ERROR 2

Troubleshooting ideas: 1. In MDI mode, set parameter P11549#0=1, and the system will automatically change to 0. After the power is turned off and restarted, the value is automatica...
share5的头像-FANUC CNC钻石会员share51个月前
05512
FANUC system black screen alarm ALM_197 alarm solution-FANUC CNC

FANUC system black screen alarm ALM_197 alarm solution

The FANUC system screen is divided into two types, one is the black screen screen, and the other is the operation screen we enter normally. When the system detects that it cannot m...
share5的头像-FANUC CNC钻石会员share51个月前
01095
FANUC SV5136 alarm maintenance summary-FANUC CNC

FANUC SV5136 alarm maintenance summary

FANUC SV5136 alarm: Cause and treatment: Compared with the number of controlled axes, the number of servo amplifiers recognized by FSSB is insufficient. 1.FSSB setting screen After...
share5的头像-FANUC CNC钻石会员share51个月前
09013