Fanuc 0i共78篇
This section mainly introduces the alarms and instructions of the FANUC 0I series
FANUC SP9032 SIC-LSI RAM FAULT-FANUC CNC

FANUC SP9032 SIC-LSI RAM FAULT

Amplifier alarm number: 32 Replace the Spindle Amplifier(SP) control printed circuit board FANUC SP9032 Description The FANUC SP9032 SIC-LSI RAM FAULT alarm usually indicates that ...
share5的头像-FANUC CNC钻石会员share546天前
0867
FANUC SP9030 OVERCURRENT-FANUC CNC

FANUC SP9030 OVERCURRENT

Amplifier alarm number: 30 Check and correct the power supply voltage. FANUC SP9030 Description The FANUC SP9030 OVERCURRENT alarm usually indicates that an overcurrent imbalance i...
share5的头像-FANUC CNC钻石会员share546天前
06514
FANUC SP9027 DISCONNECT POSITION CODER-FANUC CNC

FANUC SP9027 DISCONNECT POSITION CODER

Amplifier alarm number: 27 Replace the cable FANUC SP9027 Description The FANUC SP9027 DISCONNECT POSITION CODER alarm usually indicates that the spindle position encoder signal is...
share5的头像-FANUC CNC钻石会员share546天前
0479
FANUC SP9024 SERIAL TRANSFER ERROR-FANUC CNC

FANUC SP9024 SERIAL TRANSFER ERROR

Amplifier alarm number: 24 1 Place theCNC-to-spindle cable away from the power cable. 2 Replace the cable. FANUC SP9024 Description The FANUC SP9024 SERIAL TRANSFER ERROR is an ala...
share5的头像-FANUC CNC钻石会员share546天前
05311
FANUC SP9022 SP AMP OVER CURRENT-FANUC CNC

FANUC SP9022 SP AMP OVER CURRENT

Amplifier alarm number: 22 FANUC SP9022 1 Review operationconditions (acceleration/ deceleration and cutting)to reduce the load. 2 Check and correct the parameters. FANUC SP9022 De...
share5的头像-FANUC CNC钻石会员share547天前
04811
FANUC SP9020 EXCESS OFFSET CURRENT V-FANUC CNC

FANUC SP9020 EXCESS OFFSET CURRENT V

Amplifier alarm number: 20 FANUC SP9020  RReplace the Spindle Amplifier (SP). FANUC SP9020 Description Abnormality in a Spindle Amplifier(SP) component is detected. (Theinitial va...
share5的头像-FANUC CNC钻石会员share547天前
03612
FANUC SP9019 EXCESS OFFSET CURRENT U-FANUC CNC

FANUC SP9019 EXCESS OFFSET CURRENT U

Amplifier alarm number: 19 FANUC SP9019 Reason for the alarm: Replace the Spindle Amplifier (SP) FANUC SP9019 Description Abnormality in a Spindle Amplifier(SP) component is detect...
share5的头像-FANUC CNC钻石会员share547天前
03615
FANUC ALARM 935 (SRAM ECC ERROR)-FANUC CNC

FANUC ALARM 935 (SRAM ECC ERROR)

FANUC ALARM 935 Causes and actions An ECC error occurred in the SRAM used to store data such as parametersand machining programs. This alarm is issued if the battery has run down o...
share5的头像-FANUC CNC钻石会员share51个月前
0609
FANUC system occasionally detects SV409 alarm-FANUC CNC

FANUC system occasionally detects SV409 alarm

cause of issue An abnormal load was detected on the servo motor, Cs axis, or spindle positioning axis. troubleshooting Check the load of the axis during movement; Confirm whether t...
share5的头像-FANUC CNC钻石会员share51个月前
0686