FANUC SP9032 SIC-LSI RAM FAULT
Amplifier alarm number: 32 Replace the Spindle Amplifier(SP) control printed circuit board FANUC SP9032 Description The FANUC SP9032 SIC-LSI RAM FAULT alarm usually indicates that ...
FANUC SP9030 OVERCURRENT
Amplifier alarm number: 30 Check and correct the power supply voltage. FANUC SP9030 Description The FANUC SP9030 OVERCURRENT alarm usually indicates that an overcurrent imbalance i...
FANUC SP9027 DISCONNECT POSITION CODER
Amplifier alarm number: 27 Replace the cable FANUC SP9027 Description The FANUC SP9027 DISCONNECT POSITION CODER alarm usually indicates that the spindle position encoder signal is...
FANUC SP9024 SERIAL TRANSFER ERROR
Amplifier alarm number: 24 1 Place theCNC-to-spindle cable away from the power cable. 2 Replace the cable. FANUC SP9024 Description The FANUC SP9024 SERIAL TRANSFER ERROR is an ala...
FANUC SP9022 SP AMP OVER CURRENT
Amplifier alarm number: 22 FANUC SP9022 1 Review operationconditions (acceleration/ deceleration and cutting)to reduce the load. 2 Check and correct the parameters. FANUC SP9022 De...
FANUC SP9020 EXCESS OFFSET CURRENT V
Amplifier alarm number: 20 FANUC SP9020 RReplace the Spindle Amplifier (SP). FANUC SP9020 Description Abnormality in a Spindle Amplifier(SP) component is detected. (Theinitial va...
FANUC SP9019 EXCESS OFFSET CURRENT U
Amplifier alarm number: 19 FANUC SP9019 Reason for the alarm: Replace the Spindle Amplifier (SP) FANUC SP9019 Description Abnormality in a Spindle Amplifier(SP) component is detect...