Fanuc 0i共71篇 第7页
This section mainly introduces the alarms and instructions of the FANUC 0I series
FANUC SP9002 SSPA:02 Speed deviation is too large-FANUC CNC

FANUC SP9002 SSPA:02 Speed deviation is too large

FANUC SP9002 Reason for alarm The spindle motor speed detection value deviates far from the command speed. FANUC SP9002  troubleshooting If this alarm is displayed during motor ac...
share5的头像-FANUC CNC钻石会员share520天前
04111
Fanuc alarm: PS047 -ILLEGAL AXIS SELECT-FANUC CNC

Fanuc alarm: PS047 -ILLEGAL AXIS SELECT

Fanuc alarm: PS047 -ILLEGAL AXIS SELECT CNC Machine Control Manufacturer:Fanuc Control Model:, 16i/18i/21i, 0i-A 0i-B 0I-D 0I-F 0I-F PLUS Fanuc alarm: PS047 -ILLEGAL AXIS SELECT ...
Fanuc alarm: PS061 -P OR Q COMMAND IS NOT IN THE MULTIPLE REPETIVE CYCLES BLOCK-FANUC CNC

Fanuc alarm: PS061 -P OR Q COMMAND IS NOT IN THE MULTIPLE REPETIVE CYCLES BLOCK

Fanuc alarm: PS061 -P OR Q COMMAND IS NOT IN THE MULTIPLE REPETIVE CYCLES BLOCK CNC Machine Control Manufacturer:Fanuc Control Model:, 16i/18i/21i, 0i-A 0i-B 0I-D 0I-F 0I-F PLUS ...
share5的头像-FANUC CNC钻石会员share538天前
4115
FANUC SP9016 RAM ERROR-FANUC CNC

FANUC SP9016 RAM ERROR

Amplifier alarm number: 16 FANUC SP9016 Reason for the alarm: The RAM used for external data in the spindle amplifier is abnormal. Troubleshooting ideas: The hardware is damaged, r...
share5的头像-FANUC CNC钻石会员share516天前
04012
FANUC SP9012 OVERCURRENT POWER CIRCUIT-FANUC CNC

FANUC SP9012 OVERCURRENT POWER CIRCUIT

Amplifier alarm number: 12 Reason for the alarm: Caused by excessive current in the spindle motor. FANUC SP9012 Troubleshooting ideas: 1) Check the initialization of the inherent p...
Fanuc alarm: PS046 -ILLEGAL REFERENCE RETURN COMMAND-FANUC CNC

Fanuc alarm: PS046 -ILLEGAL REFERENCE RETURN COMMAND

Fanuc alarm: PS046 -ILLEGAL REFERENCE RETURN COMMAND CNC Machine Control Manufacturer:Fanuc Control Model:, 16i/18i/21i, 0i-A 0i-B 0I-D 0I-F 0I-F PLUS Fanuc alarm: PS046 -ILLEGAL...
Fanuc alarm: PS020 -OVER TOLERANCE OF RADIUS-FANUC CNC

Fanuc alarm: PS020 -OVER TOLERANCE OF RADIUS

Fanuc alarm: PS020 -OVER TOLERANCE OF RADIUS CNC Machine Control Manufacturer:Fanuc Control Model:, 16i/18i/21i, 0i-A 0i-B 0I-D 0I-F 0I-F PLUS Fanuc alarm: PS020 -OVER TOLERANCE ...
FANUC SP9014 SOFTWARE SERIES MISMATCH-FANUC CNC

FANUC SP9014 SOFTWARE SERIES MISMATCH

Amplifier alarm number: 14 FANUC SP9014Reason for the alarm: Using an amplifier that has not been logged in to the spindle software. Troubleshooting ideas: The spindle data was mis...
share5的头像-FANUC CNC钻石会员share516天前
0387
Fanuc alarm: PS058 -END POINT NOT FOUND-FANUC CNC

Fanuc alarm: PS058 -END POINT NOT FOUND

Fanuc alarm: PS058 -END POINT NOT FOUND CNC Machine Control Manufacturer:Fanuc Control Model:, 16i/18i/21i, 0i-A 0i-B 0I-D 0I-F 0I-F PLUS Fanuc alarm: PS058 -END POINT NOT FOUND ...