排序
FANUC SP9017 Serial spindle alarm
Amplifier alarm number: 17 FANUC SP9017 Reason for the alarm: An abnormality in the spindle amplifier ID was detected. Troubleshooting ideas:Replace the spindle amplifier. FANUC SP...
Fanuc alarm: PS032 -ILLEGAL OFFSET VALUE IN G10
Fanuc alarm: PS032 -ILLEGAL OFFSET VALUE IN G10 CNC Machine Control Manufacturer:Fanuc Control Model:, 16i/18i/21i, 0i-A 0i-B 0I-D 0I-F 0I-F PLUS Fanuc alarm: PS032 -ILLEGAL OFFS...
Fanuc alarm: PS003 – TOO MANY DIGITS
Fanuc alarm: PS003 - TOO MANY DIGITS CNC Machine Control Manufacturer:Fanuc Control Model:, 16i/18i/21i, 0i-A 0i-B 0I-D 0I-F 0I-F PLUS PS003 - TOO MANY DIGITS Alarm Description D...
Fanuc alarm: PS002 – TV PARITY ALARM
Fanuc alarm: PS002 - TV PARITY ALARM CNC Machine Control Manufacturer:Fanuc Control Model:, 16i/18i/21i, 0i-A 0i-B 0I-D 0I-F 0I-F PLUS PS002 - TV PARITY ALARM Alarm Description:...
FANUC SP9013 CPU DATA MEMORY FAULT
Amplifier alarm number: 13 FANUC SP9013 Reason for the alarm: The spindle amplifier control circuit is abnormal. Troubleshooting ideas: Confirm that the hardware is damaged and rep...
FANUC ALARM 935 (SRAM ECC ERROR)
FANUC ALARM 935 Causes and actions An ECC error occurred in the SRAM used to store data such as parametersand machining programs. This alarm is issued if the battery has run down o...
Fanuc alarm: PS062 -THE CUTTING AMOUNT IS ILLEGAL IN THE ROUGH CUTTING CYCLE
Fanuc alarm: PS062 -THE CUTTING AMOUNT IS ILLEGAL IN THE ROUGH CUTTING CYCLE CNC Machine Control Manufacturer:Fanuc Control Model:, 16i/18i/21i, 0i-A 0i-B 0I-D 0I-F 0I-F PLUS Fan...
FANUC SP9004 SSPA: 04 Power supply phase loss/fuse blown
FANUC SP9004 Reason for alarm Abnormal input power supply (abnormal power frequency, missing phase, unbalanced power supply). FANUC SP9004 troubleshooting Measure whether the m...