FANUC ALM共70篇 第2页
This section mainly introduces the alarms and detailed descriptions of each FANUC system. Through this section, you can find common alarm solutions.
FANUC SP9015 SPINDLE SWITCHING FAULT-FANUC CNC

FANUC SP9015 SPINDLE SWITCHING FAULT

Amplifier alarm number: 15 FANUC SP9015 Reason for the alarm: Caused by abnormal sequence during spindle switching/output switching. Troubleshooting ideas: 1) An alarm is issued wh...
share5的头像-FANUC CNC钻石会员share55天前
04112
FANUC SP9014 SOFTWARE SERIES MISMATCH-FANUC CNC

FANUC SP9014 SOFTWARE SERIES MISMATCH

Amplifier alarm number: 14 FANUC SP9014Reason for the alarm: Using an amplifier that has not been logged in to the spindle software. Troubleshooting ideas: The spindle data was mis...
share5的头像-FANUC CNC钻石会员share55天前
0367
FANUC SP9013 CPU DATA MEMORY FAULT-FANUC CNC

FANUC SP9013 CPU DATA MEMORY FAULT

Amplifier alarm number: 13 FANUC SP9013 Reason for the alarm: The spindle amplifier control circuit is abnormal. Troubleshooting ideas: Confirm that the hardware is damaged and rep...
share5的头像-FANUC CNC钻石会员share55天前
03213
FANUC SP9012 OVERCURRENT POWER CIRCUIT-FANUC CNC

FANUC SP9012 OVERCURRENT POWER CIRCUIT

Amplifier alarm number: 12 Reason for the alarm: Caused by excessive current in the spindle motor. FANUC SP9012 Troubleshooting ideas: 1) Check the initialization of the inherent p...
FANUC SP1220 spindleless amplifier-FANUC CNC

FANUC SP1220 spindleless amplifier

一、FANUC SP1220 Reason for alarm The cable connected to the serial spindle amplifier is disconnected, or the serial spindle amplifier has not been connected. 二、FANUC SP1220 trou...
FANUC SP9011 SSPA:11 DC LINK overvoltage-FANUC CNC

FANUC SP9011 SSPA:11 DC LINK overvoltage

FANUC SP9011 Reason for alarm The voltage of the DC section (DC bus section) of the main circuit has increased abnormally. FANUC SP9011 troubleshooting This alarm occurs when the ...
FANUC SP9010 LOW VOLT INPUT POWER-FANUC CNC

FANUC SP9010 LOW VOLT INPUT POWER

FANUC SP9010  Reason for alarm A drop in the input power supply voltage of the spindle amplifier was detected. FANUC SP9010 troubleshooting Check whether the jumper cable (CXA2A-...
FANUC SP9009 OVERHEAT MAIN CIRCUIT-FANUC CNC

FANUC SP9009 OVERHEAT MAIN CIRCUIT

一、FANUC SP9009 Reason for alarm An abnormal rise in temperature of the spindle amplifier's heat sink or power element (IPM) was detected. 二、FANUC SP9009 troubleshooting If this...
share5的头像-FANUC CNC钻石会员share58天前
04615
FANUC SP9007 SSPA:07 Overspeed-FANUC CNC

FANUC SP9007 SSPA:07 Overspeed

FANUC SP9007 Reason for alarm It is detected that the spindle motor speed exceeds 115% of the maximum speed (parameter standard setting) FANUC SP9007  troubleshooting Check the sp...